SK EN 50382-2:2011

Shtëpi » Standardizim » SK EN 50382-2:2011
SK EN 50382-2:2011
Status: Published
Gjuha: English
Faqe: 27
Publikuar: 2011-11-08
Regjistri Kombëtar:
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 50382-2:2008
CLC/TC 20
Çmim: 28 €



Titulli Shqip

Zbatimet hekurudhore -Kabllot e fuqisë, për temperaturë të lartë, ë materialeve rrotulluese hekurudhore, që kanë një performancë te veçantë ndaj zjarrit -Pjesa 2 : Kabllot një dejësh te izoluar me gomë silikoni për temperatura 120°C ose 150°C

Titulli Anglisht

Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: – 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm² to 400 mm²); – 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); – 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm² to 400 mm²); – 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 °C or 150 °C and a maximum temperature for short circuit conditions of either 250 °C or 350 °C based on a duration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 °C are used with tinned conductors, the maximum operating temperature is limited to 120 °C and, for the same technical reason, the maximum short circuit temperature is limited to 250 °C. The choice of sheath may also limit the maximum operating temperature to 120 °C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”.

Komitetet Teknike

ICS

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
 
Blej
English
Published 
2011-11-08 
27 
28 € 
PDF
Blej
Zbatimet hekurudhore -Kabllot e fuqisë, për temperaturë të lartë, të ë materialeve rrotulluese hekurudhore, që kanë një performancë te veçantë ndaj zjarrit -Pjesa 1 : Kërkesa të përgjithshme