Republika e Kosovës
Ministria e Tregtisë dhe Industrisë
Standardizim   

SK EN 50073:2010

Shtëpi » Standardizim » SK EN 50073:2010
SK EN 50073:2010
Status: Withdrawn
Gjuha: English
Faqe: 26
Publikuar: 2010-09-23
I tërhequr: 2022-02-28
Regjistri Kombëtar: 380/2022
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 50073:1999
CLC/SC 31-9
Çmim: 26 €



Titulli Shqip

Udhëzues për përzgjedhjen, instalimin, përdorimin dhe mirëmbajtjen e aparateve për zbulimin dhe matjen e gazrave të djegshëm ose të oksigjenit

Titulli Anglisht

Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

This document gives guidance on the selection, installation, use and maintenance of electrically operated Group II apparatus intended for use in industrial and commercial safety applications for the detection and measurement of: combustible gases, as described in EN 50054, EN 50057, EN 50058 or oxygen as described in EN 50104. This guide is a compilation of practical knowledge to assist the user. Combustible gas detection apparatus, fixed, transportable or portable, may be used whenever there is the possibility of a risk to life or property caused by the accumulation of a combustible gas-air mixture. Such apparatus can provide a means of reducing the risk by detecting the presence of the combustible gas and issuing suitable audible or visual warnings. It may also be used to initiate specific safety precautions (e.g. plant shutdown, evacuation, operation of fire extinguishing procedures). It is applicable to all new permanent installations and, where reasonably practicable, to existing permanent installations. It is also applicable to temporary installations, whether new or existing. This Guide is not intended, but may provide useful information, for the following apparatus intended for the measurement of oxygen deficiency which may affect human health, apparatus intended only for the detection of non-combustible toxic gases; apparatus of laboratory or scientific type intended only for analysis or measurement purposes; Apparatus intended for underground mining applications; apparatus intended only for process control applications; This Guide does not apply to the following: apparatus for the detection of explosives; apparatus intended for the detection of a potentially combustible atmosphere resulting from dust or mist in air; open path apparatus not used for point measurement

Komitetet Teknike

ICS

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.