SK EN 1998-2:2005/A1:2009/A2:2016
Status: Published
Gjuha: Albanian
Faqe: 152
Publikuar: 2016-05-11
Regjistri Kombëtar: 149/2016
Botim:
|
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 1998-2:2005/A2:2011
CEN/TC 250
|
Çmim: 61 €
|
Titulli Shqip
Eurokodi 8: Projektimi i strukturave rezistente ndaj tërmetit - Pjesa 2: Urat
Titulli Anglisht
Eurocode 8: Design of structures for earthquake resistance - Part 2: Bridges
Scope Shqip
Asnjë informacion i shtuar.
Scope Anglisht
(1) The scope of Eurocode 8 is defined in EN 1998-1:2004, 1.1.1 and the scope of this Standard is defined in 1.1.1. Additional parts of Eurocode 8 are indicated in EN 1998-1:2004, 1.1.3.
(2) Within the framework of the scope set forth in EN 1998-1:2004, this part of the Standard contains the particular Performance Requirements, Compliance Criteria and Application Rules applicable to the design of earthquake resistant bridges.
(3) This Part primarily covers the seismic design of bridges in which the horizontal seismic actions are mainly resisted through bending of the piers or at the abutments; i.e. of bridges composed of vertical or nearly vertical pier systems supporting the traffic deck superstructure. It is also applicable to the seismic design of cable-stayed and arched bridges, although its provisions should not be considered as fully covering these cases.
(4) Suspension bridges, timber and masonry bridges, moveable bridges and floating bridges are not included in the scope of this Part.
(5) This Part contains only those provisions that, in addition to other relevant Eurocodes or relevant Parts of EN 1998, should be observed for the design of bridges in seismic regions. In cases of low seismicity, simplified design criteria may be established (see 2.3.7(1)).
(6) The following topics are dealt with in the text of this Part:
Basic requirements and Compliance Criteria,
Seismic Action,
Analysis,
Strength Verification,
Detailing.
This Part also includes a special section on seismic isolation with provisions covering the application of this method of seismic protection to bridges.
(7) Annex G contains rules for the calculation of capacity design effects.
(8) Annex J contains rules regarding the variation of design properties of seismic isolator units and how such variation may be taken into account in design.
Komitetet Teknike
ICS
Direktivë
Asnjë informacion i shtuar.
Veprim Kombëtar
Asnjë informacion i shtuar.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
Blej
Published
2016-05-11
234
65 €
Eurokodi 8: Projektimi i strukturave
rezistente ndaj tërmetit – Pjesa 1: Rregulla të
përgjithshme, veprimet sizmike dhe rregullat
për ndërtesa
Published
2016-05-11
99
48 €
Eurokodi 8: Projektimi i strukturave për
rezistencën ndaj tërmetit - Pjesa 3: Vlerësimi
dhe përshtatshmëria e ndërtesave
Published
2016-05-11
85
48 €
Eurokodi 8: Projektimi i strukturave për
rezistencën ndaj tërmetit - Pjesa 4: Silosët,
çisternat dhe linjat e tubave
Published
2016-05-11
49
36 €
Eurokodi 8: Projektimi i strukturave
rezistente ndaj tërmetit – Pjesa 5: Themelet,
strukturat mbajtëse dhe aspekte gjeoteknike
Published
2016-05-11
51
38 €
Eurokodi 8: Projektimi i strukturave për rezistencë ndaj tërmetit - Pjesa 6: Kullat, shtyllat dhe oxhaqet