SK EN 50124-1:2014
Status: Withdrawn
Gjuha: English
Faqe: 55
Publikuar: 2014-07-14
I tërhequr: 2020-04-23 Regjistri Kombëtar: 305/2020
Botim:
|
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 50124-1:2001
CLC/TC 9X
|
Çmim: 38 €
|
Titulli Shqip
Zbatime hekurudhore-Vetite e izolimit-Pjesa 1: Kerkesat baze-Largesite e izolimit te hapesirave dhe linjat e humbjes per te gjitha pajisjet elektrike dhe elektronike
Titulli Anglisht
Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
Scope Shqip
Asnjë informacion i shtuar.
Scope Anglisht
The whole document deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations up to 2000 m above sea level.
Insulation coordination is concerned with the selection, dimensioning and correlation of insulation both within and between items of equipment. In dimensioning insulation, electrical stresses and environmental conditions are taken into account. For the same conditions and stresses these dimensions are the same.
OneAn objective of insulation coordination is to avoid unnecessary overdimensioning of insulation.
This standard specifies:
requirements for clearances and creepage distances for equipment;
general requirements for tests pertaining to insulation coordination.
The term equipment relates to a section as defined in 1.3.1.3: it may apply to a system, a sub-system, an apparatus, a part of an apparatus, or a physical realisation of an equipotential line.
This standard does not deal with :
distances through solid or liquid insulation;
distances through gases other than air;
distances through air not at atmospheric pressure;
equipment used under extreme conditions.
Product standards have to align with this generic standard.
However, they may require, with justification, different requirements due to safety and/or reliability reasons, e.g. for signalling, and/or particular operating conditions of the equipment itself, e. g. overhead lines which have to comply to EN 50119.
This standard also gives provisions for dielectric tests (type tests or routine tests) on equipment (see annex B).
NOTE For safety critical systems, specific requirements are needed. These requirements will be resolved in the product specific signalling standard EN 50129 (in preparation).
Komitetet Teknike
ICS
Direktivë
Asnjë informacion i shtuar.
Veprim Kombëtar
Asnjë informacion i shtuar.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
Blej
Published
2020-08-27
56
38 €
Zbatime në hekurudhë - Vetitë e izolimit - Pjesa 1: Kërkesat bazë - Largësitë e izolimit në ajër dhe të rrjedhjes për të gjitha pajisjet elektrike dhe elektronike
Withdrawn
2016-12-27
12
17 €
Zbatime hekurudhore - Vetitë e izolimit - Pjesa 2: Mbitensioni dhe mbrojtja përkatëse
Published
2020-08-27
16
20 €
Zbatime në hekurudhë - Vetitë e izolimit - Pjesa 2: Mbitensionet dhe mbrojtja përkatëse