Republika e Kosovës
Ministria e Tregtisë dhe Industrisë
Standardizim   

DS CEN/TS 14793:2013

Shtëpi » Standardizim » DS CEN/TS 14793:2013
DS CEN/TS 14793:2013
Status: Withdrawn
Gjuha: English
Faqe: 32
Publikuar: 2013-12-11
I tërhequr: 2020-04-23
Regjistri Kombëtar: 305/2020
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
CEN/TS 14793:2005
CEN/TC 264
Çmim: 29 €



Titulli Shqip

Shkarkimet nga burimet stacionare-Procedura e vlerësimit ndërlaboratorik për një metodë alternative e krahasuar me një metodë referuese

Titulli Anglisht

Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

The purpose of this technical specification is to specify a validation procedure to show if an Alternative Method (AM) can be used as an alternative to the Standard Reference Method (SRM), both implemented to determine the same measurand. This document has been drawn up for laboratories working in air pollution measurements (and consequently examples taken from this sector are included in the appendices). In particular, this Technical Specification provides the statistical tools and different criteria to evaluate the alternative method; this does not release the person responsible for this validation from bearing technical and analytical judgement on the evaluation of the different criteria. Three steps are described in the validation procedure: - description of the AM and setting of the field of equivalence (range and type of gas matrix); - determination of the performance characteristics of the AM and calculation of the overall uncertainty where appropriate and check of compliance of the maximum overall uncertainty allowed for the SRM; - check of repeatability and lack of systematic deviation of the AM in the field in comparison with the SRM for the type of matrix defined in the field of equivalence. NOTE Some parts of the second step of the validation of the alternative method should be performed by a recognised test-house. If the AM fulfils the requirement of the procedure, then the laboratory that carried out the whole validation process is allowed to use it as a SRM in the field application where the equivalence has been demonstrated. However, if the validation process involves at least 4 different accredited laboratories performing simultaneously parallel measurements in the field, and if the AM passes with success all the tests of the procedure, then this method could be proposed to CEN, who can decide to consider this AM as a new reference method (ARM). The use of this procedure implies that a reference method has been defined by the regulator or i

Komitetet Teknike

ICS

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.