Titulli Shqip
Zbatime hekurudhore -Kabllot e vagonave hekurudhorë që kanë performancë të veçantë të lëndës djegëse -Paret i hollë -Pjesa 3 : Kabllot njëzemërshe dhe shumëzemërshe (çifte, treshe dhe katërshe) të ekranizuara dhe paret i hollë i këllëfuar
Titulli Anglisht
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
Scope Shqip
Asnjë informacion i shtuar.
Scope Anglisht
EN 50306-3 specifies requirements for, and constructions and dimensions of, multicore cables, rated 300 V to earth, of the following type:
Screened (0,5 mm2 to 2,5 mm2, number of cores from 1 to 4)
All cables have stranded tinned copper conductors, and thin wall thickness, halogen-free, insulation and sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at temperatures of 90 °C or 105 °C dependent upon the sheath system type.
NOTE 1 For cables with type S2 sheath a temperature of 105 °C is only allowed when specifically tested for the higher rating (i.e. by long-term thermal endurance testing to demonstrate a lifetime of at least 20 000 h at 125 °C).
The maximum temperature for short-circuit conditions is 160 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-1 1).
NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1.
NOTE 3 EN 45545-1 is still under development and should be consulted.
EN 50306-3 should be used in conjunction with EN 50306-1, General Requirements, and EN 50306 2, Single core cables.
Komitetet Teknike
ICS
Direktivë
Asnjë informacion i shtuar.Veprim Kombëtar
Asnjë informacion i shtuar.Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
Blej
Withdrawn
2011-11-08
21
25 €
Zbatimet hekurudhore -Kabllot e vagonave hekurudhorë që kanë performancë të veçantë të lëndës djegëse -Paret i hollë -Pjesa 1 : Kërkesa të përgjithëshme
Withdrawn
2011-11-08
18
22 €
Zbatimet hekurudhore -kabllot e vagonave hekurudhorë që kanë përformancë të veçantë të lëndës djegëse -Paret i hollë -Pjesa 2 : Kabllot njëzemërshe
Withdrawn
2011-11-08
28
28 €
Zbatime hekurudhore -Kabllot e vagonave hekurudhorë që kanë performancë të veçantë të lëndës djegëse -Paret i hollë -Pjesa 4 : Kabllot shumzemërshe dhe shumëçiftëshe standard dhe paret i këllëfuar