Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2002)
Scope Shqip
Asnjë informacion i shtuar.
Scope Anglisht
ISO 2719:2002 describes two procedures, A and B, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions and other liquids. It is applicable for liquids with a flash point above 40 degrees C.
Procedure A is used for the determination of the flash point of paints and varnishes that do not form a surface film, unused lubricating oils and other petroleum products not covered by Procedure B.
Procedure B is used for the determination of the flash point of residual fuel oils, cutback bitumens, used lubricating oils, liquids that tend to form a surface film, liquids with suspensions of solids and highly viscous materials such as polymeric solutions and adhesives.
ISO 2719:2002 is not applicable to water-borne paints or liquids contaminated by traces of highly volatile materials.