Titulli Shqip
Kollonat ndriçuese - Pjesa 3 - 3: Projektimi dhe verifikimi - Verifikimi nga përllogaritjet
Titulli Anglisht
Lighting columns - Part 3-3: Design and verification - Verification by calculation
Scope Shqip
Asnjë informacion i shtuar.
Scope Anglisht
This European Standard specifies the requirements for the verification of the design of lighting columns by calculation. It applies to post top columns not exceeding 20 m height for post top lanterns and to lighting columns with brackets not exceeding 18 m height for side entry lanterns.
The calculations used in this standard are based on limit state principles, where the effects of factored loads are compared with the relevant resistance of the structure. Two limit states are considered:
a) the ultimate limit state, which corresponds to the load-carrying capacity of the lighting column;
b) the serviceability limit state, which relates to the deflection of the lighting column in service.
NOTE In following this approach, simplifications appropriate to lighting columns have been adopted, These are:
1) the calculations are applicable to circular and regular octagonal cross-sections;
2) the number of separate partial safety factors have been reduced to a minimum;
3) serviceability partial safety factors have a value equal to unity.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard.
This standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not included, this group of lighting columns will have additional requirements (see prEN 40-2).
Komitetet Teknike
ICS
Direktivë
Asnjë informacion i shtuar.Veprim Kombëtar
SK EN 40-3-3:2023
replaces
SK EN 40-3-3:2010
- 2023-05-12
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
Blej
Withdrawn
2010-10-06
23
25 €
Kollonat ndriçuese - Pjesa e 3-1:Projektimi dhe verifikimi - Specifikimet për ngsrkesat karakteristike.
Published
2023-07-25
17
22 €
Kollonat ndriçuese - Pjesa 3 - 1: Projektimi dhe verifikimi - Specifikimi për ngarkesat karakteristike
Withdrawn
2010-10-06
15
20 €
Kollonat ndriçuese -Pjesa 3 -2 : Verifikimi nga testimi
Published
2023-07-25
16
20 €
Kollonat ndriçuese - Pjesa 3 - 2: Projektimi dhe verifikimi - Verifikimi nga testimi
Published
2023-07-25
30
29 €
Kollonat ndriçuese - Pjesa 3 - 3: Projektimi dhe verifikimi - Verifikimi nga përllogaritjet
Published
2009-03-30
30
29 €
Kollona ndriçuese -Pjesa 4 : Kërkesa për kollonat e ndriçimit prej betoni të përforcuar dhe të parandeme
Published
2009-03-30
28
28 €
Kollonat e ndriçimit -Pjesa 5 : Kërkesat për kollonat e ndriçimit prej çeliku
Published
2009-03-30
25
26 €
Kollonat ndriçuese -Pjesa 6 : Kërkesat për kollonat e ndriçimt prej alumini
Published
2009-03-30
25
26 €
Kollonat ndriçuese -Verifikimi I projektit me anë të llogaritjeve -Pjesa 7 : Kërkesat për fibrat e përforcuara me polimerë të përbërë të kolonave të ndriçimit