Logo <p>Agjencia Kosovare p&euml;r Standardizim Adres&euml;: Rr. &quot;Ismail Hajdaraj&quot; p.n.10000 Prishtin&euml;/Republika e Kosov&euml;s. Tel.+ 383 38 512 779 Fax: +383 38 512 798 Email:aksinfo@rks-gov.net</p> Date: 2024-11-24
Time: 14:06


SK SSH EN ISO 5167-6:2023
Status: Published
Gjuha: English
Faqe: 27
Publikuar: 2023-01-24
Regjistri Kombëtar: 449/2023
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN ISO 5167-6:2019
CEN/SS F05
Çmim: 28 €



Titulli Shqip

Matja e rrjedhjes së lëngjeve me anë të pajisjeve diferenciale të presionit që futen në tuba me seksion rrethor të mbushur plot - Pjesa 6: Metrat pykë (ISO 5167-6:2019)

Titulli Anglisht

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2019)

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document. It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, beta (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 104. NOTE 2 A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.

Komitetet Teknike

KT-6 - KT. për Metrologji

ICS

17.120.10 - Debit në qarqet e mbyllura

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
 
Blej
English
Withdrawn 
2021-12-20 
29 
28 € 
PDF
Blej
Matja e rrjedhjes së lëngjeve me anë të pajisjeve diferenciale të presionit që futen në tuba me seksion tërthor rrethor të mbushur plot - Pjesa 5: Matësit kon (ISO 5167-5:2016)

Copyright 2019 Agjencia Kosovare për Standardizim