Logo <p>Agjencia Kosovare p&euml;r Standardizim Adres&euml;: Rr. &quot;Ismail Hajdaraj&quot; p.n.10000 Prishtin&euml;/Republika e Kosov&euml;s. Tel.+ 383 38 512 779 Fax: +383 38 512 798 Email:aksinfo@rks-gov.net</p> Date: 2024-11-22
Time: 00:30


SK EN 14394:2005+A1:2017
Status: Published
Gjuha: English
Faqe: 133
Publikuar: 2017-10-18
Regjistri Kombëtar: 206B/2017
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 14394:2005+A1:2008
CEN/TC 57
Çmim: 55 €



Titulli Shqip

Kaldaja për ngrohje - Kaldajat me djegës me shfryrës ajri - Fuqia termike nominale më e vogël ose e barabartë me 10 MW dhe temperatureë maksimale të punës prej 110oC

Titulli Anglisht

Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

This European Standard specifies the requirements and test methods for the design, manufacturing, safe operation and the rational energy usage for standard boilers and low temperature boilers (with "boiler" in the sense of "boiler body") from steel and cast iron to be equipped with separately marketed forced draught burners according to the relevant burner standards (for automatic forced draught burners for gaseous fuels see EN 676 and for atomising oil burners see EN 267) up to a nominal heat output of 10 MW. They are operated, either with negative pressure (natural draught boiler) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer''s instructions." This European Standard specifies requirements for boilers with normal operating temperatures between 100 °C and 110 °C and has a "dual structure": - For boilers where the shut off temperature of the safety temperature limiter does not exceed 110 °C the Pressure Equipment Directive (PED) requires" Sound Engineering Practice", - For boilers where the shut off temperature of the safety temperature limiter exceeds 110 °C this European Standard specifies the requirements of the PED as stated in Annex ZB. NOTE 1 The "maximum allowable temperature TS" is defined in the PED and its Guidelines." Boilers in accordance with this European Standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is up to 110 C and the maximum safety temperature limiter of 120 C. The maximum allowable operating pressure is 10 bar. This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensation boilers, boilers with oil vaporisation burners. For these boilers there are further requirements. For gas-fired central heating boilers equipped with a forced draught burner of nominal heat out put not exceeding 1000 kW,

Komitetet Teknike

KT-8 - KT. për Energji

ICS

01.040.91 - Ndërtimi dhe materialet e ndërtimit (Fjalorë)
91.140.10 - Sisteme të ngrohjes qendrore

Direktivë

97/23/EC - Pajisje të trysnisë
2014/68/EU - Direktiva 2014/68 / EU e Parlamentit Evropian dhe e Këshillit e datës 15 maj 2014 mbi harmonizimin e ligjeve të Shteteve Anëtare në lidhje me bërjen te disponueshme në treg të pajisjeve nën presion

Veprim Kombëtar

Asnjë informacion i shtuar.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
 
Blej
English
Withdrawn 
2012-09-27 
131 
55 € 
PDF
Blej
Kaldaja për ngrohje -Kaldajat me djegës me shfryrës ajri -Fuqia termike nominale më e vogël ose e barabartë me 10 MW dhe temperaturë maksimale të punës prej 110 °C

Copyright 2019 Agjencia Kosovare për Standardizim