Logo <p>Agjencia Kosovare p&euml;r Standardizim Adres&euml;: Rr. &quot;Ismail Hajdaraj&quot; p.n.10000 Prishtin&euml;/Republika e Kosov&euml;s. Tel.+ 383 38 512 779 Fax: +383 38 512 798 Email:aksinfo@rks-gov.net</p> Date: 2024-11-22
Time: 03:37


SK EN 15621:2013
Status: Withdrawn
Gjuha: English
Faqe: 42
Publikuar: 2013-12-23
I tërhequr: 2020-10-01
Regjistri Kombëtar: 327/2020
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 15621:2012
CEN/TC 327
Çmim: 34 €



Titulli Shqip

Ushqimet per kafshe -Përcaktimi i kalciumit, natriumit, fosforit, magnezit, kalium, squfurit, hekurit, zinkut, bakrit, manganit, kobal tit, dhe molibdenit pas tretjes nën presion me ICP -AES

Titulli Anglisht

Animal feeding stuffs - Determination of calcium, sodium, phosphorus, magnesium, potassium, sulphur, iron, zinc, copper, manganese and cobalt after pressure digestion by ICP-AES

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

This European Standard specifies a method for the determination of the minerals calcium, sodium, phosphorus, magnesium, potassium and sulphur and the elements iron, zinc, copper, manganese, cobalt in animal feeding stuffs by inductively coupled plasma atomic emission spectrometry (ICP-AES) after pressure digestion. The method was fully statistically tested and evaluated within 11 animal feeding stuff samples for the minerals calcium, sodium, phosphorus, magnesium, potassium and sulphur and the elements iron, zinc, copper, manganese and cobalt. For potassium and sulphur the HORRAT values were mostly higher than 2. Therefore, for these elements the method is more applicable as a screening method and not for confirmatory purposes. Other elements like molybdenum, lead, cadmium, arsenic were not fully statistically tested and evaluated within 11 animal feeding stuff samples because these elements did not occur in concentrations higher than the limit of quantification in most of these samples. A single laboratory validation is therefore necessary for the use of this multi element method for these elements. The method limit of quantification for each element is dependent on the sample matrix as well as on the instrument. The method is not applicable for determination of low concentrations of elements. A limit of quantification of 1 mg/kg should normally be obtained. NOTE This method can also be used for the determination of minerals in products with high mineral content (> 5 %), yet for this purpose other more precise analytical techniques are available.

Komitetet Teknike

KT-12 - KT. për Teknologji Agroushqimore

ICS

65.120 - Ushqime për kafshët

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.
Copyright 2019 Agjencia Kosovare për Standardizim