Logo <p>Agjencia Kosovare p&euml;r Standardizim Adres&euml;: Rr. &quot;Ismail Hajdaraj&quot; p.n.10000 Prishtin&euml;/Republika e Kosov&euml;s. Tel.+ 383 38 512 779 Fax: +383 38 512 798 Email:aksinfo@rks-gov.net</p> Date: 2024-11-22
Time: 03:49


SK EN 14394:2012
Status: Withdrawn
Gjuha: English
Faqe: 131
Publikuar: 2012-09-27
I tërhequr: 2017-07-06
Regjistri Kombëtar: 95/2012
Botim:
Standardet ndërkombëtare që kanë lidhje
This standard is identical to:
EN 14394:2005
CEN/TC 57
Çmim: 55 €



Titulli Shqip

Kaldaja për ngrohje -Kaldajat me djegës me shfryrës ajri -Fuqia termike nominale më e vogël ose e barabartë me 10 MW dhe temperaturë maksimale të punës prej 110 °C

Titulli Anglisht

Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C

Scope Shqip

Asnjë informacion i shtuar.

Scope Anglisht

This European Standard specifies the requirements and test methods for the construction, the safety and the rational energy usage for heating boilers (standard-heating and low temperature boilers) fired by liquid fuels from steel and cast iron with burners according to the relevant burner standards (for atomising oil burners, see. EN 267) up to a nominal heat output of 10 MW. They are operated, either with negative pressure (natural draught boiler) or with positive pressure (pressurised boiler) in the combustion chamber, in accordance with the boiler manufacturer''s instructions Boilers in accordance with this European Standard are designed for the heating of central heating installations in which the heat carrier is water, and the maximum allowable operating temperature of which is up to 110 °C and the maximum safety temperature limiter of 120 °C. The maximum allowable operating pressure is 10 bar. This standard does not apply to gas boilers with atmospheric burners, boilers for solid fuels, oil or gas fired condensation boilers, boilers with oil vaporisation burners. For these boilers there are further requirements. For gas-fired central heating boilers equipped with a forced draught burner of nominal heat out put not exceeding 1000 kW, see prEN 303-7. For shell boilers with a nominal heat output exceeding 10 MW and a maximum safety temperature limiter exceeding 120 °C, see EN 12953 series. NOTE Definitions for heating boiler and low temperature boiler see Council Directive 92/42/EEC.

Komitetet Teknike

KT-10 - KT. për Makineri

ICS

01.040.91 - Ndërtimi dhe materialet e ndërtimit (Fjalorë)
91.140.10 - Sisteme të ngrohjes qendrore

Direktivë

Asnjë informacion i shtuar.

Veprim Kombëtar

Asnjë informacion i shtuar.

Shënimet

Standardi SK EN 14394:2012, i adoptuar ne KT.Makineri shfuqizohet dhe i njëjti kalon me "mirror" ne KT.Energji.
Numri Standardit
Gjuha
Status
Publikuar
Faqe
Çmim
 
Blej
English
Published 
2017-10-18 
133 
55 € 
PDF
Blej
Kaldaja për ngrohje - Kaldajat me djegës me shfryrës ajri - Fuqia termike nominale më e vogël ose e barabartë me 10 MW dhe temperatureë maksimale të punës prej 110oC

Copyright 2019 Agjencia Kosovare për Standardizim